Fully Submersible Safety Battery System

Immersion liquid cooling technology verifies that PACK is a product with high safety performance. The battery pack is completely immersed in insulating oil-based coolant. The battery cell is in direct contact with the coolant, and the heat is taken away through liquid circulation to ensure that the battery cell always operates within the optimal temperature range. It can be widely used in industrial and commercial, large storage systems, UPS systems, and other scenarios, and has considerable application prospects.

Category:
Share

Related products

No data

 
 

Product Features

Ultimate safety
The battery is immersed in liquid 360 ° to completely eliminate safety hazards in the battery system, truly achieving intrinsic safety


Efficient heat dissipation
The high heat capacity and high thermal conductivity of the immersion liquid can achieve faster heat transfer of the battery, ensuring that the battery always operates within the optimal temperature range and extending the service life of the battery cell and system


System temperature difference
Immersion cooling has the ability to cool the entire battery surface, improve the uniformity of battery surface temperature, and achieve a temperature difference of ≤ 2 ℃


Protection level
IP68 protection level, preventing leakage of PACK during transportation and installation, ensuring stable operation of the system


Environmentally friendly
Using oil-based coolant, high purity, low volatility, biodegradable, friendly to personnel/environment/organisms, and compatible with most materials


Modular design
Plug and play, easy to transport, install, and maintain, with full temperature and voltage acquisition function for individual battery cells

 

Technical Parameters

PACK Parameters Specification
Nominal Energy (kWh)   46.592
Rated Charge and Discharge Power (kW) 23.296
Charge and Discharge Rate (P) 0.5
Battery Parameters Specification
Battery Type Lithium Iron Phosphate
Battery Capacity (V/A) 3.2/280
Grouping Method 1P52S
Rated Voltage (V) 166.4
Voltage Range (V) 145.6 ~ 187.2
Basic Parameters Specification
Cooling Method Immersion Liquid Cooling
Immersion Liquid Flow Rate (L/min) 5
Voltage And Temperature Collection Quantity 52 Points Each
Operating Temperature Range (℃) Charging: 0 ~ 50 Discharging: -30 ~ 55
Storage Temperature Range (℃) -30 ~ 55
Battery Temperature Difference (℃) ≤ 2
Ambient Humidity (%) <95(No Condensation)
Protection Level IP 68